Implant Practice US provides continuing education and other valuable resources to help you build upon your expertise in implantology. Our continuing education is updated regularly and accessible any time, from anywhere.
Purchase a subscription today!

Implant-supported overdentures

Continuing Education (CE)

The continuing education article below is available to Implantologists and general dental practitioners who perform implants.

In order to earn continuing education credits with our publication, you must be a paid subscriber of Implant Practice US and complete a short quiz about the content of the article.

Earn up to 16 online dental CE credits per year! Purchase a subscription now.

Drs. Brenda Baker and David Reaney discuss the factors to consider during overdenture treatment planning

Educational aims and objectives

This clinical article aims to discuss factors to consider during overdenture treatment planning.

Expected outcomes

Implant Practice US subscribers can answer the CE questions to earn 2 hours of CE from reading this article. Correctly answering the questions will demonstrate the reader can:

  • Identify factors that govern the planning of the overdenture treatment.
  • Recognize indications for attachment-retained treatment.
  • Realize conditions that should exist to ensure optimized restorative treatment.
  • Identify some forms of retention for implant-retained overdentures.
  • Identify some attachment selection alternatives.
  • Realize various treatment considerations for maxillary and mandibular implant overdentures.

An implant-retained overdenture is a removable dental prosthesis that is supported by the residual oral tissues and employs dental implants for retention. Implant-retained overdentures are a treatment alternative for many patients for whom conventional dentures are poorly tolerated. They may be indicated in patients with changed anatomy, neuromuscular disorders, significant gag reflexes, or considerable ridge resorption (Vere, Bhakta, and Patel, 2012).

Life expectancy is increasing globally, and people are becoming edentulous at later stages, so partial edentulism is becoming more commonplace until old age (Vasant and Vasant, 2013). Implant-retained overdentures may reduce residual ridge resorption and enhance mastication and hence nutritional status, improve speech, and patient self-esteem (Doundoulakis, et al., 2003).

Factors that govern the planning of the overdenture treatment follow:

  • The number and length of the implants
  • Quality and quantity of the anchoring bone tissue
  • Economic constraints

Indications for attachment-retained treatment (Dentsply):

  • An unfavorable jaw relation that makes treatment with a fixed bridge restoration difficult
  • Esthetic problems, e.g., the need for lip support in the upper jaw
  • Phonetic problems due to loss of alveolar bone in the upper jaw
  • Patient dissatisfaction with removable denture due to oral irritations and/or loss of bone for denture fixation
  • A bridge option makes satisfactory oral hygiene impossible or extremely difficult to achieve
  • Edentulous patients with a cleft palate

To ensure an optimized restorative treatment, the following conditions should exist:

  • Parallel implants
  • If a rigid bar connector is used, ensure there are no large distances between implants
  • Appropriate length of extension bars, not too long
  • Adequate resilience of the mucosa; the mucosa should not be too soft
  • Provide an even load on the mucosa when the prosthesis is in function

Retention of implant-retained over-dentures

Overdentures may be retained by a number of different implants, which can be splinted or separate (Dudic and Merickse-Stern, 2002). Authors have reported high implant survival rates for mandibular overdentures, and thus, successful treatment outcomes when overdentures are retained by two implants (Meijer, et al., 2009) splinted or non-splinted. In the maxilla, the evidence base supports the use of four to six implants splinted with a bar, although free-standing abutments are increasing in popularity (Galluci, Morton, and Weber, 2008).

There are various prosthetic options and attachments that are available to provide a satisfactory overdenture. The success of the implant-supported overdenture will depend on the correct position and distribution of the supporting implants. These considerations have a direct effect on the selection of the attachment for each particular situation.

Attachment selection

The different attachment assemblies follow.

Bar and clip systems
The major bar types come with matching clips. These are incorporated into the prosthesis, either at the time of processing or afterwards as a pickup procedure. Some systems include a spacer that can be incorporated at processing. The use of the spacer enables a space between the clip and the bar when the prosthesis is at rest in the patient’s mouth. Upon biting, the denture is capable of some vertical movement so that there is some support for occlusal loads instead of purely implant support.

A milled bar is classified as a rigid attachment. Milled bars do not allow movement of the denture base and can provide relief over painful areas such as superficial mental nerves (Dudic and Merickse-Stern, 2002). A cast bar may be made including proprietary components, or a custom design can be fabricated. Subsequently, the denture is made to fit over the custom design.

Resilient bars, when appropriately designed, allow a single axis of rotation, use greater mucosal support, and offer greater protection to the retentive attachments. Both rigid and resilient bars can be used to align nonparallel implants. However, they need at least 10 mm of interocclusal clearance and should not be used when vertical space is limited (Chee and Jivraj, 2006). The Hader Bar, which is a semi-precision bar attachment that provides hinge movement provided by only a single Hader Bar, has been used in the attachment assembly design (Shafie, 2007).

The Dolder Bar is a prefabricated precision bar attachment that comes in two forms:

  • The rigid form is U-shaped with parallel walls. The resilient form is egg-shaped in cross section and provides vertical and hinge resiliency.
  • The resilient Dolder Bar is also called a bar joint. The Dolder Bar is indicated for overdenture patients with adequate or relatively large inter-ridge space.

Studs
If stud attachments are used, there are important considerations regarding stud attachment alignment:

  • All stud attachments should be parallel to each other, and the attachments should not interfere with the path of insertion of the overdenture.
  • It is harder to achieve an ideal alignment with taller attachments than shorter ones.

Either synthetic rubber rings or metal lamellae are included in the prosthesis. When the prosthesis is inserted, they flex sufficiently to engage into a circular undercut on a metal post that is part of an abutment screwed into an implant. The LOCATOR® Overdenture stud attachment (Zest Dental Solutions™) was designed for easy insertion and removal, dual retention, a low vertical profile, and its pivoting ability, so it was resilient and tolerant for implant divergence. Many patients can bite their overdenture into place at an angle and can cause damage, which may require replacement. For this reason, the LOCATOR attachment was designed to be self-aligning.

As a result of these design features, in 2010 it became available for many different implants from varied manufacturers. A new generation of implants called overdenture implants has been introduced into implant dentistry (Mericske-Stern, et al., 2000). The main design difference between overdenture implants and traditional implants is that part of the stud attachment either male or female has been combined in the implant body.

Magnets
Magnets provide the least retention and have two main disadvantages:

  • The retentive force produced reduces sharply as the distance between the elements increases beyond very close contact (100 microns).
  • Over a period of time, there is a loss of magnetic attraction, sometimes accompanied by corrosion (Preiskel and Preiskel, 2009).

Telescopic copings (rigid and nonrigid)
Note: Patients with advanced resorption of the ridge are suitable for bar or telescopic attachment assemblies that offer horizontal stability. Patients with minimal alveolar resorption of the ridge are suitable for studs or magnetic attachment assemblies.

Maxillary implant overdentures have different treatment considerations than mandibular implant overdentures — as when maxillary bone resorbs and atrophies, this may restrict implant placement. The resorption of the residual ridge area in the mandible, however, may often allow the use of implants anteriorly due to substantial basal bone in terms of width and depth in that area.

Treatment considerations for man-dibular implant overdentures

The following treatment concepts have been summarized by Sadowsky (2001).

The mandibular overdenture retained by implants in the area between the foramina maintains bone in the anterior mandible. The average annual bony ridge height physiological shrinkage is about 0.4 mm in the edentulous anterior mandible. Studies have revealed better patient-based results when two-implant supported mandibular overdentures have been used compared with conventional lower dentures. In 2002, McGill consensus published that the treatment modality of choice for the edentulous mandible should be a two-implant retained overdenture (Feine, et al., 2002). Vere, Bhakta, and Patel stated: “Two free-standing implants in the canine regions, as the simplest option, would appear to be the treatment of choice to retain an overdenture in the edentulous mandible” (2012).

The anterior mandibular bone under an implant overdenture may resorb at the rate of 0.5 mm over 5 years, and long-term resorption may remain at 0.1 mm per annum (Jemt, et al., 1996; Quirynen, et al., 1992; Naert, et al., 1998). Bone undergoes remodeling in the anterior mandible as a result of more functional loading with implants.

In younger patients or those edentulous for less than 10 years, a fixed implant denture may preserve posterior bone better than an implant overdenture in the lower jaw. Many patients with mandibular implant overdentures can experience a loss of fit of their maxillary complete dentures and need upper full denture relines. There can be a transfer of significant occlusal forces onto the anterior maxilla with maxillary bone resorption and soft tissue inflammation. The deleterious forces could generate more midline fractures in the maxillary denture. There should be no anterior contact in the centric relation position and minimal anterior contact in lower excursive movements. Frequent recalls to assess stability and retention should be scheduled.

Retention, stability, and chewing function improve only slightly with an implant-supported mandibular overdenture as compared with an implant-mucosa–supported overdenture.

Multiple implants can be recommended for the mandibular overdenture when there is a/an:

  • Dentate maxilla
  • High-retention needs
  • Implant length less than 8.0 mm
  • Implant width less than 3.5 mm

When two implants are used in the anterior mandible to retain an overdenture, solitary ball attachments are more economical, easier to clean than bars that are more retentive, less technique sensitive, and more suitable for tapered arches. Mucosal hyperplasia is less likely to develop with solitary ball attachments.

Overdentures retained by two implants in the anterior mandible need more maintenance during the first year than in later years. Whether the ball or bar design requires more maintenance is controversial.

There appears to be no statistical difference when comparing long-term maintenance of mandibular implant overdentures retained by two implants in contrast to those retained by three or more implants. Patients are happier with mandibular implant overdentures than with complete dentures, even when patients had preprosthetic surgery. Magnets retaining mandibular implant overdentures are associated with less happy patients than those who wear bars or ball attachments as there are more post-insertion visits due to corrosion or wear. Patients appear to be equally happy with a fixed implant complete denture or a removable implant overdenture on the mandible. Patients who value stability more than hygiene select a fixed prosthesis.

Treatment considerations for maxillary implant overdentures

A systematic literature review by Sadowsky SJ (2007) sought evidence to establish criteria to treat the edentulous maxilla with implant overdentures. The following findings were reported.

Maxillary implant overdentures have a higher rate of implant loss than any other implant procedures. This has been thought to be a result of relatively poor bone quality and quantity, increased implant-to-
abutment ratios, and non-axial loading. For this reason, more implants are placed in the maxilla. Delayed loading of four to six splinted implants in the maxilla is advised by Galluci, Morton, and Weber, who reported implant survival rates of 94.8%-97.7% after 10 years (2009). Ideally, implants in the maxilla should be widely distributed symmetrically about the arch, but this may be compromised by various anatomical issues such as pneumatization of the maxillary sinus, alveolar orientation, and the shape of the ridge.

Maxillary implant overdenture treatment is often compromised by reduced bone quantity/quality, and higher biomechanical forces occur. Maxillary implants are often angled buccally due to resorption. The replaced teeth are usually arranged anterior and inferior to the residual ridge. The implants are often opposed by natural teeth in the anterior and premolar regions, and the cantilever forces can be destructive.

As there is limited space in the maxilla, flexible bar designs may increase bending moments. As the masticatory mucosa is thicker on the maxilla, longer implant abutments are often needed, which increases the lever arm. Thin buccal bone of the rigid maxilla may not tolerate the applied forces as well as the mandible. There are no specific recommendations for the number of implants needed to support a maxillary overdenture. If the design of the denture is such that there is no palatal coverage, then a minimum of four implants is considered necessary.

Grafting procedures and modified implant placements have been done to overcome compromised maxillary jaw volume limiting implant length. There has been low implant failure reported when severely resorbed maxillae are augmented with sinus grafts. The placement of implants in an angulated position has been suggested if implants are splinted.

The use of the zygomatic or pterygo-maxillary implants have been well documented in the atrophied maxilla with the use of fixed restorations. Palatal placement of zygomatic implants can cause over-
contouring and unusual substructure designs for overdenture patients with the possible need for angled abutments and/or placement of the connecting bar buccally to the abutment. Zygomatic implants can be useful where there is extensive pneumatization of the maxillary sinuses (Jivraj, Chee, and Corrado, 2006).

A broadly distributed implant-supported design across the anterior premolar region and tuberosities produces better stress transfer to the underlying bone than a dense number of implants in the anterior region supporting a cantilever. Bars with distal cantilevers can increase the forces on the terminal implants by more than 3 times. Unsplinted anchorage systems may need less space within the prosthesis, facilitate hygiene, be more cost-effective, less technique sensitive, and easier to manage than splinted designs. There is no significant difference in mean bone loss between subjects with ball- or bar-retained overdentures.

At least 13.0 mm-14.0mm is needed from the implant platform to incisal edge for a bar design. This is comprised of 4.0 mm for the bar, 1.00 mm below the bar, and room for clip and acrylic/ tooth assembly. The span length should not exceed 18.0 mm, with a 2.0 mm vertical stiffener height below the round portion.

The use of attaching mechanisms such as a bar clip requires a minimum distance of 10.0 mm-12.0 mm between implants, or a milled bar with a frictional fit superstructure is needed. A single anchor will need 10.0 mm-11.0 mm space above the implant platform to the incisal tip and permit more flexibility with location. Bars provide more retention than solitary anchors when loaded with both vertical and oblique forces. Implant angulation may compromise the retention of solitary anchors.

Magnets have poor retention but may be suitable for bruxers or patients with difficulty manipulating the prosthesis. Patients appear to be equally satisfied with bars or solitary anchors retaining a maxillary implant overdenture. There is a high incidence of hyperplasia with bars.

Maxillary implant overdentures have a high rate of complications and may need more post-insertion maintenance than implant-supported bridges. Most complications occur in the first year. Mucosal inflammation and mechanical problems (especially in cases without palatal coverage) occur more often in the maxilla than the mandible. This may be due to bigger stresses in the maxilla from the opposing dentition or fixed restorations. The most common complication occurs as there is a change in the retention system due to loosening or fracture. Many retention system fractures occur in bruxers. There may be limitations in the design and material failure due to insufficient vertical space for prosthetic parts as well as morphological and speech factors. Bars are recommended when restoring divergent implants of more than 10 degrees.

Patients prefer a palateless long-bar overdenture design to a fixed implant denture. Most patients prefer a removable prosthetic design as they are familiar with the shape, and it is easier phonetically. A tissue-borne overdenture needs fewer implants than a fixed complete denture and may be more attractive economically. In patients who have a moderate to severe resorption in the maxilla who want a rigid prosthesis that is esthetic and cleansable may find a milled bar-retained implant-supported prosthesis suitable. Studies have shown that the individual length of implants is more critical than the complete length of supporting implants for implant survival.

Implant-retained overdentures are a most important and useful treatment modality for many patients. A variety of retention systems are available. Some systems link implants while others do not. When a system is selected, the dentist and support teams have to consider the medical history and general wellness of the patient, biofunctional, maintenance, and financial requirements.

Author Info

Brenda Baker, BDS (Hons), MSc, graduated from Sydney University with honors and completed a master’s degree in conservative dentistry from Eastman Dental College. She has taught in the prosthetic faculty at Sydney University and pursued a preventively oriented career in private practice. Dr. Baker is currently director of clinical education for Southern Cross Dental.

David Reaney, BDS (Edin), DGDP(UK), MClinDent (Prosthodontics), graduated with distinction from the University of Edinburgh. He has held the position of clinical lecturer at the School of Dentistry, Royal Victoria Hospital in Belfast and is currently in private practice in Moy, Northern Ireland. Dr. Reaney is general manager of Southern Cross Dental.

References

  1. Jivraj S, Chee W, Corrado P. Treatment planning of the edentulous mandible. Br Dent J. 2006;  201(5):261-279.
  2. Attachment-retained restorations: ASTRA TECH Implant System™ EV [Clinical and laboratory manual]. United States: DENTSPLY International; 2015. EV [online] available at https://www.dentsplyimplants.com.au/~/media/M3%20Media/DENTSPLY%20IMPLANTS/Product/1219974%20Attachment_retained%20restorations%20ASTRA%20TECH%20Implant%20System%20EV.ashx.  Accessed November 3, 2016.
  3. Doundoulakis JH, Eckert SE, Lindquist CC, Jeffcoat MK. The implant-supported overdenture as an alternative to the complete mandibular denture. J Am Dent Assoc. 2003;134(11):1455-1458.
  4. Dudic A, Mericske-Stern R. Retention mechanisms and prosthetic complications of implant-supported mandibular overdentures: long-term results. Clin Implant Dent Relat Res. 2006;4(4): 212-219.
  5. Feine JS, Carlsson GE, Awad MA, Chehade A, Duncan WJ, Gizani S, et al. The McGill consensus statement on overdentures. Montreal, Quebec, Canada. Int J Prosthodont. 2002;15(4):413-414.
  6. Gallucci GO, Morton D, Weber HP. Loading protocols for dental implants in edentulous patients. Int J Oral Maxillofac Implants. 2008;24(suppl): 132-146.
  7. Jemt T, Chai J, Harnett J, Heath MR, Hutton JE, Johns RB, et al. A 5-year prospective multicenter follow-up report on overdentures supported by osseointegrated implants. Int J Oral Maxillofac Implants. 1996;11(3): 291-298.
  8. Jivraj S, Chee W, Corrado P. Treatment planning of the edentulous maxilla. Br Dent J. 2006; 201(5):261-279.
  9. Meijer HJ, Raghoebar GM, Batenburg RH, Vissink A. Mandibular overdentures supported by two Brånemark, IMZ or ITI implants: a ten-year prospective randomized study. J of Clin Periodont. 2009; 36(9):799-806.
  10. Mericske-Stern R, Venetz E, Fahrländer F, Bürgin W. In vivo force measurements on maxillary implants supporting a fixed prosthesis or an overdenture: a pilot study. J Prosthet Dent. 2000;84(5): 535-547.
  11. Naert I, Gizani S, Vuylsteke M, van Steenberghe D. A 5-year randomized clinical trial on the influence of splinted and unsplinted oral implants in the mandibular overdenture therapy. Part I: Peri-implant outcome. Clin Oral Implants Res. 1998;9(3): 170-177.
  12. Preiskel HW, Preiskel A. Precision attachments for the 21st century. Dent Update. 2009;36(4):  221-227.
  13. Quirynen M, Naert I, van Steenberghe D, Dekeyser C, Callens A. Periodontal aspects of osseointegrated fixtures supporting a partial bridge. An up to 6-years retrospective study. J Clin Periodontol. 1992;19(2):  118-126.
  14. Sadowsky, SJ. Mandibular implant-retained overdentures: a literature review. J Prosthet Dent. 2001; 86(5):468-473.
  15. Sadowsky, S J. Treatment considerations for maxillary implant overdentures: a systematic review. J Prosthet Dent. 2007;97(6):340-348.
  16. Shafie HR. Clinical and Laboratory Manual of Implant Overdentures. John Wiley & Sons; 2013.
  17. Vasant R, Vasant MK. Retention systems for implant-retained overdentures. Dent Update. 2012; 40(1):28-31.
  18. Vere J, Bhakta S, Patel R. Implant-retained overdentures: a review. Dent Update. 2012; 39(5): 370-372.

Stay Relevant With Implant Practice US

Join our email list for CE courses and webinars, articles and mores

SUBSCRIBE TODAY

Implant Practice US is a leading dental journal and publication for dental implantology continuing education, oral implantology case studies, and more. Subscribe to Implant Practice US today!

ONLINE DENTAL CE

Earn dental continuing education credits as an Implant Practice US subscriber. Log in for online dental CE credits now!

Other Dental Publications

AGD PACE MedMark White

SUBSCRIBE TODAY

Implant Practice US is a leading dental journal and publication for dental implantology continuing education, oral implantology case studies, and more. Subscribe to Implant Practice US today!

ONLINE DENTAL CE

Earn dental continuing education credits as an Implant Practice US subscriber. Log in for online dental CE credits now!

Other Dental Publications

Copyright © 2024 Orthodontic Practice US - Dental Journal and Online Dental CE | MedMark LLC
15720 North Greenway Hayden Loop, Suite #9 Scottsdale, AZ 85260 | All rights Reserved | Privacy Policy | Terms & Conditions

Shopping Cart
Scroll to Top